Wednesday, August 14, 2019
Breaker Failure Detection Algorithms Research Paper
Breaker Failure Detection Algorithms - Research Paper Example The second part addresses issues worth consideration when applying Breaker Failure Protection and lastly, advances towards breaker Failure Protection. Using algorithms significantly enhance the numerical BF protection. Introduction Contingency analysis remains to be one of the great tasks that face protection engineers. The reason to this is due to the fact that a Protection Engineer has to focus on Murphyââ¬â¢s Law and Ohms Law concurrently. The design for PRS plays a key role in detecting any fault that happens on the power system and the possibilities of eruption of any fault in the protection system of the power system. When the protective relay system is order, the designers of the power system understand it but the condition changes when a failure is detected. Deriving solutions towards this failure is what makes a protection engineer proficient. The protection engineer can only succeed by understanding how operations of the system. The best approach that the engineer can ha ve is to have a proper understanding of each component of the system as well as their interaction and overlaps needed. The need for Breaker Failure Protection To successfully analyze this topic, the differences between fault detection devices and fault interruption devices should be understood. Any disturbances like faults are detected by protective relays. The protective relays works in either way, interfere with the fault current system or cuts off any connection to the power system. Systems that lack breaker failure detection fail to analyze detection and interruption failures. This is not the case for breaker failure detection. The redundant relay systems play the role of detecting fault in case of failure (IEEE 8). What to consider for Breaker Failure Protection Before considerations necessary for breaker failure detection, aspects of back up protection need to be focused. The aspects include speed, sensitivity and user friendliness together with maintenance required. Sensitivi ty The question considered under this aspect is on the reliability of remote relays in detecting faults in the power system. A difficulty arises when analyzing the conditions that lead to system failure. The hindering factor is the load encroachment. The radial system has limitations in the fault current and the circuit load. The source acts as a controlling factor thereby making this system simple. Complications arise for networked systems. The possibilities of the relays detecting failure past the remote bus is limited because of the in feed. To solve this issue, a remote backup through distance relays with applications in the adjacent zones seems appropriate. This leads to change in the reach setting of the in feed to long ones. Complexities arise when the zone three relays are relied on as a backup protection. When breaker failure protection and a normal back up are applied, the problem is solved (Daume, Jon 20). Speed Speed of the system in clearing faults that arise due to fai lure of the primary protection is vital. Over tripping of the system is prevented by the time taken by the relays in overlapping zones. The outcome to this process is for a remote back up to be set up after a reasonable delay. When breaker failure protection is used, tripping of back up circuit breakers is quickened. The set up speed of the system is guided by damage that is likely to be incurred on equipment, quality of power and its impact on its environs and stability. Incase
Subscribe to:
Post Comments (Atom)
No comments:
Post a Comment
Note: Only a member of this blog may post a comment.